CMP Sovereign (HDSS)

The Sovereign cable cleats are metallic cable cleats which have been designed, constructed, and tested in accordance with the International Standard IEC 61914: Cable cleats for electrical installations. The Sovereign cable cleat has been designed and tested for high short circuit conditions on cables held in trefoil application / formation, to ensure the securing and retention of cables without damage.
The range is fabricated from 316L stainless steel, giving it high creep strength whilst providing excellent corrosion resistance in the harshest of environments. The Sovereign cable cleat is available for trefoil application/ formation for diameters of 17mm to 128mm in 24 sizes.

The cleat has one M12 and two M10 fixing clearance holes within its base, allowing versatility to the installer during installation, and is designed to enable the product to be secured to a variety of mounting surfaces. The hinge opens fully, allowing the cables to be easily placed within the cable cleat, to aid the installer before closing and securing via the mouth piece bolt.

Liners come as standard which help to restrain the cable(s) within vertical applications. Where thermal elongation of cables occurs, the liner also provides a layer of protection between the cable sheath and the cable cleat during normal operation. This additional layer protects the cable from chafing on any mounting surface due to differential movements such as those found in marine and offshore applications. The liners also assist in the extra protection of cable(s) in the event of short circuit fault conditions. The standard liners supplied are classified as Low Smoke and Fume Zero Halogen (LSF0H) and Phosphorus-Free.

Показать больше Показать меньше
Характеристики
Загрузки
Рекомендуемые товары
  • Категория
    Кабельный гланд
  • Design Specification
    IEC 61914
  • Cable Type
    6.1.3 Composite HDSS - Heavy Duty Stainless Steel
  • Материал
    316L Stainless Steel with Standard Liner Standard liners are classified as Low Smoke & Fume (LSF), Zero Halogen (LS0H) and Phosphorus Free
  • Needle Flame Test
    Pass - 120 second flame application time IEC 61914 clause 10.0, 10.1, IEC 60695-11-5
  • Impact Resistance
    Pass - Very heavy IEC 61914 clause 6.3, 6.3.5, 9.2
product_files_1